Measuring Salt Contamination using the Bresle Method (Bresle Kit) in Accordance with ISO 8502-6 / ISO 8502-9
It is essential that the level of contaminants on a surface is measured prior to application of the coating to ensure the quality of the coating and that its optimum lifetime is achieved.
If the coating is applied to a contaminated surface, which is not properly prepared, it could fail prematurely resulting in costly re-coating and high maintenance costs.
The Elcometer 138 Bresle Kit includes the Elcometer 138 Conductivity Meter. This lightweight, portable conductivity meter accurately measures the salinity of the test samples.
The cartridge type sensor can be easily replaced when necessary and displays conductivity (µS/cm and mS/cm) and salinity (%) on the digital display.
Features of the meter include indication of stability of reading indication.
Elcometer 135B Bresle Patches
Technical Specification :
Can be used in accordance with
AS 3894.6-A, IMO MSC.215 (82), IMO MSC.244 (83), ISO 8502-6, ISO 8502-9, SSPC Guide 15, US Navy NSI 009-32, US Navy PPI 63101-000
- See more at: www.multilab.biz
If the coating is applied to a contaminated surface, which is not properly prepared, it could fail prematurely resulting in costly re-coating and high maintenance costs.
KIT CONTENTS | |
T13818515 | Elcometer 138 Conductivity Meter |
E135----B | Bresle Patches (Box of 25) |
T13818517 | 3 x 5ml (0.1fl oz) Syringes |
T13818518 | 3 x Needles |
T13818519 | Plastic Beaker 30ml (1fl oz) |
T13818516 | 4 x Calibration Standards Solution |
T99911344 | Pure Water 250ml (8.5fl oz) |
The cartridge type sensor can be easily replaced when necessary and displays conductivity (µS/cm and mS/cm) and salinity (%) on the digital display.
Features of the meter include indication of stability of reading indication.
Elcometer 135B Bresle Patches
Part Number | Description |
E138----1 | Elcometer 138 Bresle Salt Kit |
Tests per Kit | 25 |
Dimensions | 300 x 220 x 75mm (11 x 8.6 x 3”) |
Weight | 2.1kg (4.62lb) |
Measuring Range | 2% full scale ±1 digit. At a depth of more than 10mS/cm, the range is 3% full scale ±1 digit |
Packing List | Box of 25 x Elcometer Bresle patches, 250ml pure water in clear plastic bottle, 3 x 5ml (0.1fl oz) syringes, 3 x blunt needles, 30ml (1fl oz)plastic beaker, Elcometer 138 Conductivity Meter, 2 x CR2032 lithium batteries, 2 x standard solution (1.41 mS/cm), moistening solution, purified water, pipette, conductivity meter storage pouch, carry case and operating instructions |
AS 3894.6-A, IMO MSC.215 (82), IMO MSC.244 (83), ISO 8502-6, ISO 8502-9, SSPC Guide 15, US Navy NSI 009-32, US Navy PPI 63101-000